Direct Spark Ignition (DSI) Control Board
Microprocessor-Based
Controls Combustion, Blower and Indoor Motors
Spark Igniter and the Gas Valve
Monitors Timing, Trial for Ignition, Flame Sensing and Lockout
100 Percent Lockout Safety Feature
Compatible with LP or Natural Gas
Status LED for Fault Codes to Aid in Troubleshooting
Made in USA
Controls Gas Valve, Igniter, Blower Motor, Inducer, Humidifier and Air Cleaner
Microprocessor-Based Precision
Designed for 100 Percent Gas Shutoff in Case of Ignition Failure
Twinning Compatible with Another ICM2808 Control
Reverse Polarity Protection
Secondary Brownout Voltage Protection
Compatible with 24 Volt AC Standard Thermostat
Provides Dual-Color Diagnostic LED to Aid in Troubleshooting
Made in USA
Controls Gas Valve, Igniter, Blower Motor, Inducer, Humidifier and Air Cleaner
Microprocessor-Based Precision
Designed for 100 Percent Gas Shut-Off in Case of Ignition Failure
Twinning Compatible with Another ICM2807 Control
Reverse Polarity Protection
Secondary Brownout Voltage Protection
Compatible with 24 Volt AC Standard Thermostat
Continuous Blower Speed Jumper
Limit Switch Lockout Time
Limit Switch Lockout after Power Interruption
Self-Diagnostics
Provides Diagnostic LEDs to Aid in Troubleshooting
Made in USA
Low Cost Form
Microprocessor-Based Precision
Diagnostic Leds Aid in Testing and Troubleshooting
Made in USA
Universal Integrated Furnace Control offers universal compatibility and diagnostics. It replaces a large number of furnace control models in single-stage warm air furnaces. Uses 120Vac hot surface igniter. Includes instructions and special wire harnesses for easy replacement
Cross reference and wire harnesses provided for simple replacement over 195 existing furnace controls
Main burner ignition using a 120V hot surface igniter
Flame rectification circuit to monitor flame presence
Monitoring of system pressure switch, high temperature limit, and rollout functions
Appliance operation/safety requirements controlled via microprocessor
Controls circulating fan motor based on appliance requirements, in response to a conventional low voltage thermostat
LED system status, performance and diagnostic indication
Twinning capability
Compact-Smaller footprint allows for a better fit and easier installation
Universal-One defrost control for nearly every single stage heat pump to reduce inventory and increase profitability
This universal control replaces more than 260 OEM and competitive models
Easy Setup-Save time with a dual LED display that simplifies configuration
Quite Mode-Customers will appreciate the quiet operation
Replaces over 400 White-Rogers, Robertshaw and Honeywell intermittent pilot ignition modules
Provides ignition sequencing, flame monitoring and safety shutoff for intermittent pilot warm air furnaces and heating appliances
Provides 100% pilot gas shutoff if pilot fails to light
After 6-minute delay, trial for ignition is repeated
Ignition trial/delay sequence is repeated until the appliance lights or call for heat is removed
For use with Natural or LP gas
For use in single rod or dual rod/remote sense applications
Includes spark cable adapters to allow field replacement of both Honeywell and competitive controls without replacing existing spark cable
S8910U 3000 Series has LED Status Indicator and Microammeter Ports for Easy Troubleshooting
For Local (Single Rod) or Remote (Dual Rod) Rectification Type Flame Sensing
Contains Easy-To-Use Cross Reference and Instructions Plus the Accessories Required to Replace the Existing Hot Surface Ignition Module
Low Cost
Controls Inducer and Blower Fan Motor, Hot Surface Igniter and Gas Valve
Monitors Timing, Trial for Ignition, Flame Sensing, Pressure and Limit Switch and Lockout
Designed for 100 Percent Gas Shutoff in Case of Ignition Failure
Reverse Polarity Protection
Compatible with 24 Volt AC Standard Thermostat
Compatible with LP or Natural Gas
Provides Diagnostic LED to Aid in Testing or Troubleshooting
Made in USA
Controls Inducer and Blower Control
Designed for 100 Percent Gas Shutoff in Case of Ignition Failure
Monitors Timing and Gas Valve