ActionsUse with Honeywell Flame Safeguard Primary Safety Controls and Burners Requiring Ultraviolet Flame Detection
C7027 Mounts on a 1/2 Inch Sighting Pipe by Using an Integral Collar
Detectors Can be Wired in Parallel for Difficult Sighting Applications
C7027 Seals Against Pressures up to 5 PSI When Correctly Installed
Allows for Blast Tube Mounting Due to Compact Size
Use with Honeywell Flame Safeguard Primary Safety Controls and Burners Requiring Ultraviolet Flame Detection
Mounts on a 1 Inch Sighting Pipe by Using an Integral Collar
Protects the Sensing Tube with a Shield
Wires in Parallel for Difficult Sighting Applications
Seals Against Pressures as High as 5 PSI When Correctly Installed
Field-Replaceable Ultraviolet Sensing Tube
Use with Honeywell Flame Safeguard Primary Safety Controls and Burners Requiring Ultraviolet Flame Detection
C7027 Mounts on a 1/2 Inch Sighting Pipe by Using an Integral Collar
Detectors Can be Wired in Parallel for Difficult Sighting Applications
C7027 Seals Against Pressures up to 5 PSI When Correctly Installed
Allows for Blast Tube Mounting Due to Compact Size
Use with Honeywell Flame Safeguard Primary Safety Controls and Burners Requiring Ultraviolet Flame Detection
C7027 Mounts on a 1/2 Inch Sighting Pipe by Using an Integral Collar
Detectors Can be Wired in Parallel for Difficult Sighting Applications
C7027 Seals Against Pressures up to 5 PSI When Correctly Installed
Allows for Blast Tube Mounting Due to Compact Size
Use with Honeywell Flame Safeguard Primary Safety Controls and Burners Requiring Ultraviolet Flame Detection
C7027 Mounts on a 1/2 Inch Sighting Pipe by Using an Integral Collar
Detectors Can be Wired in Parallel for Difficult Sighting Applications
C7027 Seals Against Pressures up to 5 PSI When Correctly Installed
Allows for Blast Tube Mounting Due to Compact Size
The Small Size of these Devices Enable their Application to Flame Detection in Installations where Space is Limited
the Holder and Flame rod Assemblies Facilitate Flame Proving on Gas Burners or Gas Ignited Oil Burners which are Controlled by Electronic Flame Safeguard Systems
Use on Industrial Flame-Retention Gas Burner Nozzles
Works with Honeywell Flame Safeguard Controls Requiring Rectification Type Flame Detector
Mounts in Areas with Limited Space Because Flame Rod Can be Cut to Desired Length
Uses Rajah Electrical Connector
Uses thermistor sensing element in ventilation duct systems
Negative temperature coefficient (NTC) causes resistance to decrease as sampled air temperature increases
Requires no settings or calibration
Mounts on mounting bracket with four screws (not supplied)