S2K Commerce - Products Dropdown
S2K Commerce - Order Entry
Controls oil burner, oil valve and the ignition transformer in response to a call for heat
Solid state flame sensing circuit
LED on terminal strip indicates system lockout
Enclosed safety switch with external reset button
Manual trip lever opens safety switch for system maintenance
For mounting on a standard 4 in. x 4 in. junction box or direct mounting on burner housing
Use to Troubleshoot System Operation
Platinum Positive Temperature Coefficient Sensor
Factory Calibrated
No Settings or Field Calibration Required
Solid State Elements Sense Enthalpy (Temperature and Humidity), Use Two Sensors for Differential Control, Maximizing Energy Savings
Use One Sensor in Outdoor Air for Single Sensor Control, Use Two Sensors, One in Return Air and One in Outdoor Air for Differential Control
Mount in any Position up to 200 Ft (61 M) Away from Economizer Logic Module
Upon Application Oof Power, Load is Energized Immediately
When Thermostat Opens or on Power Interruption, Load is De-Energized and Time Delay Initiates
Load will be Energized Again after Delay Time has Elapsed
Cut Jumper for 120/240 Volt AC Circuit. Leave Jumper for 24 Volt AC Circuit
Upon Application of Power the Time Delay Initiates
Completion of Selected Delay Period the Load is Energized
Timer will Reset on Power Interruption or when Thermostat Disconnects
Cut Jumper for 120/240 Volt AC circuit. Leave Jumper for 24 Volt AC Circuit. Multi-Purpose Delay on Make Timing
Protects Air Conditioning, Refrigeration and Heat Pumps from Damage which may be Caused by Short Cycling of Compressor
For Compressor Staging and Stagger Starting Multiple Units
Helps to Reduce Power Surges in Multiple Compressor Applications