S2K Commerce - Products Dropdown
S2K Commerce - Order Entry
Unit mounted C7400S enthalpy sensor includes solid state temperature and humidity sensors
Outputs a digital communicating signal on a two-wire Sylkbus communications link, reporting the temperature and humidity separately to the controller
The controller determines the enthalpy (total heat), enabling economizer modes of operation when outside air enthalpy is suitable for free cooling
Enthalpy sensors are compatible with Honeywell economizer systems
When used with an economizer, the enthalpy boundary curve is programmed via the controller
When the temperature and humidity are determined to be suitable based on the relationship to the boundary, the controller allows outside air for economizing
Dual enthalpy sensors in outside air and return switches the controllers to economizer mode of operation anytime the outside enthalpy is less than the return air enthalpy
The C7250 Mixed Air Sensor is Designed for Use as a 20K Input to a Controller for Mixed Air Temperature in Rooftop Packaged Air Conditioning Equipment
Plugs Directly into Wall Outlet
Lamp Plugs into Receptacle at Bottom of Winter Watchman Device
Useful When House is Unoccupied to Notify a Neighbor of a Temperature Drop So Heating Source Fault Can be Rectified before Freeze-Up Occurs
Not Precision Calibrated for Use as a Thermostat
Use in Intermittent Ignition Applications
Capable of Zone Control with Zone Valves
Circulator Zone Control with Zach and or Terminals on R8182D,E,H,J 8 Flame Failure During the Running Cycle Results in a 45 Second Attempt to Restart
If Unsuccessful, Safety Shut-Off Occurs, Requiring Manual Reset before Burner Can be Restarted
R8182D,E,F Mount Directly on Burner
R8182H,J Mount on 4 x 4 in Junction Box and Include 5 Foot (1.5 Meter) Armored Capillary with Remote Sensor
C554A Cadmium Sulfide Flame Detector and a 24 Volt AC Thermostat Required
Controls oil burner, oil valve and the ignition transformer in response to a call for heat
Solid state flame sensing circuit
LED on terminal strip indicates system lockout
Enclosed safety switch with external reset button
Manual trip lever opens safety switch for system maintenance
For mounting on a standard 4 in. x 4 in. junction box or direct mounting on burner housing
Use to Troubleshoot System Operation
Platinum Positive Temperature Coefficient Sensor
Factory Calibrated
No Settings or Field Calibration Required
Solid State Elements Sense Enthalpy (Temperature and Humidity), Use Two Sensors for Differential Control, Maximizing Energy Savings
Use One Sensor in Outdoor Air for Single Sensor Control, Use Two Sensors, One in Return Air and One in Outdoor Air for Differential Control
Mount in any Position up to 200 Ft (61 M) Away from Economizer Logic Module
Upon Application Oof Power, Load is Energized Immediately
When Thermostat Opens or on Power Interruption, Load is De-Energized and Time Delay Initiates
Load will be Energized Again after Delay Time has Elapsed
Cut Jumper for 120/240 Volt AC Circuit. Leave Jumper for 24 Volt AC Circuit
Upon Application of Power the Time Delay Initiates
Completion of Selected Delay Period the Load is Energized
Timer will Reset on Power Interruption or when Thermostat Disconnects
Cut Jumper for 120/240 Volt AC circuit. Leave Jumper for 24 Volt AC Circuit. Multi-Purpose Delay on Make Timing
Protects Air Conditioning, Refrigeration and Heat Pumps from Damage which may be Caused by Short Cycling of Compressor
For Compressor Staging and Stagger Starting Multiple Units
Helps to Reduce Power Surges in Multiple Compressor Applications