Flashing LED on detector head indicates normal operation
Magnet test capability (magnet included)
More wiring space than competitive models
Footprint allows easy retrofit in many applications without additional drilling
Duct wall gaskets on back of enclosure are pre-installed
Compatible with the WP-2000 weatherproof enclosure
Reset switch is also an alarm test switch - competitive models require a magnet or cover removal to test at unit
Unit includes green pilot and red alarm visual indicators
External mounting tabs do not require cover removal to install
Colored cover gasket indicates proper cover seal
Compact, lightweight size means easy handling, lower shipping costs
Large terminal connection screws
Standard interchangeable "plug-in" UL268 photoelectric or ionization heads
Advanced detector head design yields internal dust filtering
No additional screens or filters to clean
Compatible with building automation and fire alarm systems
Ionization and Photoelectric versions available
Complete wiring details permanently attached to unit
Made in USA
Simplified installations with multi-speed fans, inaccessible air handlers, fan motors with voltage or phase different from controlled equipment
Eliminated wiring to system fan
Polyester film sail mounted on a micro switch snap switch
Removable spring counterbalances sail to allow mounting in either vertical (up or down) or horizontal air flow
Top and bottom conduit knockouts for wiring convenience
Low air velocity switch operation makes at 250 fpm and breaks at 75 fpm
Models with setpoint adjustment
Models with occupied/unoccupied override (bypass) with LED
Models with 3-position (auto/0/1) or 5-position (auto/0/1/2/3 speed) fan switch
LONWORKS network jack on all models except the TR21 and TR21-A models
Solid State Thermistor Element Provides Accurate Sensing of Temperature Changes
Unit mounted C7400S enthalpy sensor includes solid state temperature and humidity sensors
Outputs a digital communicating signal on a two-wire Sylkbus communications link, reporting the temperature and humidity separately to the controller
The controller determines the enthalpy (total heat), enabling economizer modes of operation when outside air enthalpy is suitable for free cooling
Enthalpy sensors are compatible with Honeywell economizer systems
When used with an economizer, the enthalpy boundary curve is programmed via the controller
When the temperature and humidity are determined to be suitable based on the relationship to the boundary, the controller allows outside air for economizing
Dual enthalpy sensors in outside air and return switches the controllers to economizer mode of operation anytime the outside enthalpy is less than the return air enthalpy
The C7250 Mixed Air Sensor is Designed for Use as a 20K Input to a Controller for Mixed Air Temperature in Rooftop Packaged Air Conditioning Equipment
Plugs Directly into Wall Outlet
Lamp Plugs into Receptacle at Bottom of Winter Watchman Device
Useful When House is Unoccupied to Notify a Neighbor of a Temperature Drop So Heating Source Fault Can be Rectified before Freeze-Up Occurs
Not Precision Calibrated for Use as a Thermostat
Use in Intermittent Ignition Applications
Capable of Zone Control with Zone Valves
Circulator Zone Control with Zach and or Terminals on R8182D,E,H,J 8 Flame Failure During the Running Cycle Results in a 45 Second Attempt to Restart
If Unsuccessful, Safety Shut-Off Occurs, Requiring Manual Reset before Burner Can be Restarted
R8182D,E,F Mount Directly on Burner
R8182H,J Mount on 4 x 4 in Junction Box and Include 5 Foot (1.5 Meter) Armored Capillary with Remote Sensor
C554A Cadmium Sulfide Flame Detector and a 24 Volt AC Thermostat Required