System Diagnostic LED with Fault Recall
Twinning Connection
Fused to Protect Low Voltage System Transformers
Selectable Continuous Fan Speed
2-Stage Cooling Y2 Input
Direct OEM replacements designed for high volume major brand control
Diagnostic LED indicators streamline installation and system troubleshooting
120 Volt air cleaner output and 120 Volt humidifier output up to 1 Amp maximum
Replaceable automotive style fuse
Includes flash code diagnostics
fused to protect low voltage system transformers
Interface Harnesses for Simple Conversion
Integrates Control of All Combustion Blower and Circulating Fan Operation in Gas Warm Air Appliance
Replaceable Fuse
DIP Switch Selectable Heat and Cool Delay on and Off Times
LED lights for Easy Diagnostics
Electronic Air Cleaner and Humidifier Terminal Connection
Continuous Low Speed Indoor Air Circulation
Controls Gas Valve, Igniter, Blower, Inducer, Humidifier and Air Cleaner
Diagnostic LED Indicators Streamline Installation and System Troubleshooting
120 Volt Air Cleaner Output and 120 Volt Humidifier Output up to 1 Amp Max
Replaceable Automotive Style Fuse
Reduces Inventory by Providing Maximum Control Replacement Coverage
Diagnostic LED Indicators Streamline Installation and System Troubleshooting
120 Volt Air Cleaner Output and 120 Volt Humidifier Output Up to 1 Amp Max
Factory Standard Safety Timings and Adjustable Fan Delay Options
Replaceable Automotive Style Fuse
Pushbutton Fault History Retrieval
Heat Fan Off Delay (Dipswitch Selectable), Fan on Delay for Cooling
Furnace Status LED Tri-Color
Heat Fan off Delay
Fan on Delay for Cooling
Auto Second Stage Delay
Historical Fault Retrieval by Pushbutton
YLO, Y, W1, W2, R, G, C, Twin Terminals
Pressure Switch Inputs and Monitoring
Flash Microprocessor with Non-Volatile Memory
Flame Current Measurement Points
Direct Spark Ignition (DSI) Control Board
Controls Induced Draft, Air Cleaner, Humidifier Output, Spark Igniter and Gas Valve
Monitors Timing, Trial for Ignition, Flame Sensing and Lockout
100 Percent Lockout Safety Feature
Compatible with LP or Natural Gas
Status LED for Fault Codes to Aid in Troubleshooting
Made in USA
Direct Spark Ignition (DSI) Control Board
Microprocessor-Based
Controls Combustion, Blower and Indoor Motors
Spark Igniter and the Gas Valve
Monitors Timing, Trial for Ignition, Flame Sensing and Lockout
100 Percent Lockout Safety Feature
Compatible with LP or Natural Gas
Status LED for Fault Codes to Aid in Troubleshooting
Made in USA
Controls Gas Valve, Igniter, Blower Motor, Inducer, Humidifier and Air Cleaner
Microprocessor-Based Precision
Designed for 100 Percent Gas Shutoff in Case of Ignition Failure
Twinning Compatible with Another ICM2808 Control
Reverse Polarity Protection
Secondary Brownout Voltage Protection
Compatible with 24 Volt AC Standard Thermostat
Provides Dual-Color Diagnostic LED to Aid in Troubleshooting
Made in USA
Controls Gas Valve, Igniter, Blower Motor, Inducer, Humidifier and Air Cleaner
Microprocessor-Based Precision
Designed for 100 Percent Gas Shut-Off in Case of Ignition Failure
Twinning Compatible with Another ICM2807 Control
Reverse Polarity Protection
Secondary Brownout Voltage Protection
Compatible with 24 Volt AC Standard Thermostat
Continuous Blower Speed Jumper
Limit Switch Lockout Time
Limit Switch Lockout after Power Interruption
Self-Diagnostics
Provides Diagnostic LEDs to Aid in Troubleshooting
Made in USA
Low Cost Form
Microprocessor-Based Precision
Diagnostic Leds Aid in Testing and Troubleshooting
Made in USA
Universal Integrated Furnace Control offers universal compatibility and diagnostics. It replaces a large number of furnace control models in single-stage warm air furnaces. Uses 120Vac hot surface igniter. Includes instructions and special wire harnesses for easy replacement
Cross reference and wire harnesses provided for simple replacement over 195 existing furnace controls
Main burner ignition using a 120V hot surface igniter
Flame rectification circuit to monitor flame presence
Monitoring of system pressure switch, high temperature limit, and rollout functions
Appliance operation/safety requirements controlled via microprocessor
Controls circulating fan motor based on appliance requirements, in response to a conventional low voltage thermostat
LED system status, performance and diagnostic indication
Twinning capability