ZGB060S4EX-P CT866 230V 1PH 5T 150KB 14 SEER DD ECM G/E PKG IECC

Item #: 83964 
Manufacturer Item: ZGB060S4EX-P
Manufacturer: ARMSTRONG AIR COMMERCIAL
57000 BTU/Hr Cooling, 208/230 VAC 1-Phase, 14 SEER/11 EER, R-410A, Packaged Gas/Electric Rooftop Unit
83964

Quick and Easy Retrofit - Fast installation for replacement of many existing rooftop units - fits high volume competitor's roof curbs

R-410A Refrigerant - Environmentally friendly

Single Speed Scroll Compressor - Furnished on 036 through 060 models

Allows rooftop units to deliver just the necessary amount of cooling needed to meet the space's demand

Eco-Last Coil System - Smaller, lighter condenser coil

High Pressure Switch - Protects compressor

Direct Drive (ECM) or Belt Drive Blower Motors - Multi-tap ECM direct drive motors (all 036 thru 060 models)

Belt drive motors (036 thru 074 3-Phase models) Two-speed belt drive motor (low static/high static) 074 models maximizes air performance

Downflow or Horizontal Airflow - Easy field conversion

Two Fork Lift Slots on Three Sides - Easy to pick up and transport units from almost any angle

Corrosion Resistant Drain Pan - Provides application flexibility, durability and improved serviceability

Common Components - Many maintenance items are standard throughout the entire product line, reducing the need to carry different parts to the job or maintain in inventory

Cooling System Cooling Capacity Specify nominal cooling capacity of the unit

All control voltage is provided via a 24V (secondary) transformer with inline fuse protection

Heat/Cool Staging

Capable of up to 2-heat/2-cool staging with a thermostat

Night Setback Mode Saves energy by closing outdoor air dampers and operating supply fan on thermostat demand only

Cabinet - Heavy Gauge steel panels and full perimeter heavy gauge galvanized steel base rail provides structural integrity for transportation, handling and installation

Base rails have rigging holes Three sides of the base rail have fork slots

Raised edges around duct and power entry openings in the bottom of the unit provide additional protection against water entering the building

Airflow Choice Units are shipped in downflow (vertical) configuration, can be field converted to horizontal airflow configuration without the need of a kit

Power Entry Electrical lines can be brought through the unit base or through horizontal access knock-outs

Exterior Panels - Constructed of heavy gauge, galvanized steel with a two-layer enamel Painted finish

Insulation All panels adjacent to conditioned air are fully insulated with non- hygroscopic fiberglass insulation

Access Panels Access panels are provided for the compressor, heating, controls, blower and air filter/economizer section

Single Packaged Units-Commcercial

Approval
CSA (Canada and US), UL
Cooling Capacity
58300 BTU/Hour (Gross), 57000 BTU/Hour (Net)
Current Rating
38 Amp (MCA), 50 Amp (MOP), 22.1 Amp Rated Load/12
Enclosure Finish
Galvanized, 2-Layer Enamel Painted
Enclosure Material
Steel
Frequency Rating
60 Hertz
Installation
Cabinet
Number of Phases
1
Operating Temperature
35 to 125 Deg F
Power Rating
(1) 1/4 HP (Outdoor Coil Fan Motor)
Temperature Control Type
Thermostat
Type
2 Stage, Standard Efficiency, ECM Direct Drive, Hi
Voltage Rating
208/230 Volt AC
Weight
592 Pound