Z6_GHK6HJC0OG6S20Q8HU3K6R0G63
Z7_GHK6HJC0OG6S20Q8HU3K6R0GM5
Z7_GHK6HJC0OG6S20Q8HU3K6R0GM7
Z7_GHK6HJC0OG6S20Q8HU3K6R0Q22
Home  >  HVAC Service Parts  >  Heating Parts Service  >  Specialty Controls  > R8182D1079/U PROTECTORELAY

R8182D1079/U PROTECTORELAY

Item #: 72503 
Manufacturer Item: R8182D1079/U
Manufacturer: RESIDEO-ADEMCO
5-1/4" x 3-7/16" x 7-1/8", 120 VAC 60 Hz, 200 PSI Immersion Well, Gas Media, SPST, Multi-Function, Combination Protectorelay and Hydronic Heating Controller
72503

Use in Intermittent Ignition Applications

Capable of Zone Control with Zone Valves

Circulator Zone Control with Zach and or Terminals on R8182D,E,H,J 8 Flame Failure During the Running Cycle Results in a 45 Second Attempt to Restart

If Unsuccessful, Safety Shut-Off Occurs, Requiring Manual Reset before Burner Can be Restarted

R8182D,E,F Mount Directly on Burner

R8182H,J Mount on 4 x 4 in Junction Box and Include 5 Foot (1.5 Meter) Armored Capillary with Remote Sensor

C554A Cadmium Sulfide Flame Detector and a 24 Volt AC Thermostat Required

Specialty Controls

Type
Multi-Function
Application
Oil Fired Hydronic Heating System
Item
Protectorelay and Hydronic Heating Controller
Applicable Standard
UL, CSA
Switch Type
SPST
Temperature Rating
130 to 240 Deg F (High Limit), 110 to 220 Deg F (L
Pressure Rating
200 PSI (Immersion Well)