RZ096381 20" FAN BLADE

Refrigerant - Units operate with chlorine-free, ozone friendly, R-410A
Outdoor Coil Fan - Direct drive fan(s) moves large volumes of air uniformly through entire condenser coil(s) for high refrigerant cooling capacity
Upward discharge of air reduces operating sound levels and prevents damage to lawns, shrubs and walkways
Fan motors are totally enclosed, overload protected and equipped with a rain shield
Fan service access is accomplished by removal of fan guard(s) or removal of access panel
Copper Tube/Enhanced Fin Coil - Units are equipped with a wrap-around "U" shaped coil (072-090-120 models) or two "L" shaped coils
Coils are constructed of precisely spaced ripple-edge aluminum fins machine fitted to seamless copper tubes
Lanced fins provide maximum exposure of fin surface to air stream resulting in excellent heat transfer
Fins equipped with collars that grip tubing for maximum contact area
Flared shoulder tubing connections and machine brazed silver soldering provide tight, leak-Proof joints
Long life copper tubing is corrosion-resistant and easy to field service
Thoroughly factory tested under high pressure to ensure leak-Proof construction
Completely accessible for cleaning
High Pressure Switch - Shuts off unit if abnormal operating conditions cause discharge pressure to rise above setting
Protects the compressor from excessive condensing pressure
Manual reset
Loss of Charge Switch - Shuts off unit if liquid line pressure falls below setting
Provides loss of charge and freeze-up protection
Automatic reset
Hi-Capacity Drier - Drier traps moisture or dirt that could contaminate the refrigerant system
Refrigerant Lines and Service Valves - Suction and liquid lines are located on corner of unit cabinet and are made with sweat connections
Fully serviceable suction and liquid line service valves provide complete service access to refrigerant system
Suction valve can be fully shut off, while liquid valve can be front seated to manage refrigerant charge while servicing system Accessible outside of unit cabinet
Compressor - Compressor features high efficiency with uniform suction flow, constant discharge flow and high volumetric efficiency and quiet operation
Compressor consists of two involute spiral scrolls matched together to generate a series of crescent shaped gas pockets between them
During compression, one scroll remains stationary while the other scroll orbits around it
Gas is drawn into the outer pocket the pocket is sealed as the scroll rotates
Crankcase Heater - Crankcase heater(s) prevents migration of liquid refrigerant into compressor(s) and ensures proper compressor lubrication
Cabinet - Heavy gauge, pre-painted steel cabinet provides superior rust and corrosion protection
Removable panels allow access for unit servicing
Heavy Duty steel base channels raise the unit off of mounting surface away from damaging moisture Unit lifting holes and forklift slots furnished in base rails