S2K Commerce - Products Dropdown
S2K Commerce - Order Entry
Time Initiated
Positive Slider Bar Switch Design Assures Positive Electrical Contact and Wipes the Contact Surface of Contaminates
Temperature or Pressure Terminated Models are Designed for Defrost Termination Using an External Temperature or Pressure Device
Safety Back-Up-Mechanical Time Driven Defrost Termination
Heavy Duty Synchronous Design Drive Motor
Heavy Duty Steel Enclosure with Knockouts (on the Bottom, Back and Sides) and Hasp and Staple Padlock
Adjustable Frequency of Defrost Initiation from 1 to 6 Cycles Per Day with a Minimum of 4 Hours between Successive Operations
Adjustable Back-Up Defrost Termination from 4 to 110 Minutes in 2 Minute Increment
Time Initiated
Positive Slider Bar Switch Design Assures Positive Electrical Contact and Wipes the Contact Surface of Contaminates
Temperature or Pressure Terminated Models are Designed for Defrost Termination Using an External Temperature or Pressure Device
Safety Back-Up-Mechanical Time Driven Defrost Termination
Heavy Duty Synchronous Design Drive Motor
Heavy Duty Steel Enclosure with Knockouts (on the Bottom, Back and Sides) and Hasp and Staple Padlock
Adjustable Frequency of Defrost Initiation from 1 to 6 Cycles Per Day with a Minimum of 4 Hours between Successive Operations
Adjustable Back-Up Defrost Termination from 4 to 110 Minutes in 2 Minute Increment
Time Initiated
Positive Slider Bar Switch Design Assures Positive Electrical Contact and Wipes the Contact Surface of Contaminates
Temperature or Pressure Terminated Models are Designed for Defrost Termination Using an External Temperature or Pressure Device
Safety Back-Up-Mechanical Time Driven Defrost Termination
Heavy Duty Synchronous Design Drive Motor
Heavy Duty Steel Enclosure with Knockouts (on the Bottom, Back and Sides) and Hasp and Staple Padlock
Adjustable Frequency of Defrost Initiation from 1 to 6 Cycles Per Day with a Minimum of 4 Hours between Successive Operations
Adjustable Back-Up Defrost Termination from 4 to 110 Minutes in 2 Minute Increment
Rated to 30,000 Cycles for Refrigeration Controllers with Switches
Easy Programming, Easy Set-Up, Set Time, Set Defrost Start and Defrost End
100 Hours of Power Loss Protection for Both Time and Defrost Schedule
Real-Time Clock
Lighted Display Shows Defrost Start Time and Duration
System Status Indicator
LED Indicators for Defrost and Refrigeration Cycles
Built-In Permanent Housing Protects Components from Damage
Mounts into Existing Paragon Enclosures, No Tools Required
Real Time Clock Face for Easy Accurate Settings
Defrost Times Programmable in 15-Minute Intervals with Captive Trippers
Time initiated
temperature, pressure or time terminated models available
Positive slider bar switch design assures positive electrical contact and wipes the contact surface of contaminates
Temperature or pressure terminated models are designed for defrost termination using an external temperature or pressure device
Safety back-up - mechanical time-driven defrost termination
Heavy Duty synchronous design drive motor
Choice of three contact arrangements
Adjustable frequency of defrost initiation from 1 to 6 cycles per day with a minimum of 4 hours between successive operations
Adjustable back-up defrost termination from 4 to 110 minutes in 2 minute increments Heavy Duty steel enclosure with knockouts (on the bottom, back and sides) and hasp and staple padlock
Laser-Welded Stainless Steel Bellow
Fixed or Adjustable Temperature Setting
High Amperage Contact
Pneumatic Action Provided by Vapor Filled Capillary or Capillary with Bulb Sensing Element
Anti-short cycle compressor delay for cooling applications
LCD read-out for sensor temperature, control settings, and relay status
High Amp output relay (FLA 16 Amps at 120V AC and 8 Amps at 208/240V AC) 1-Stage
EEPROM memory retains control settings during power outages
Keypad lockout to prevent end-user alteration of settings 8 foot lead with sensor is extendable up to 400 feet using 18 or 22-gauge thermostat wire
Easy 4-step set-up
Heavy Duty relay is 1 HP rated
White backlight on display
Sensor rated IP67 for dust and water (<1m) resistance
Anti-Short Cycle Compressor Delay for Cooling Application
LCD Read-Out for Sensor Temperature, Control Settings and Relay Status
EEPROM Memory Retains Control Settings During Power Outages
Keypad Lockout to Prevent End User Alteration of Settings
Easy 4-Step Set-Up
Off Position
Laser-Welded Stainless Steel Bellow
Fixed or Adjustable Temperature Setting
High Amperage Contact
Pneumatic Action Provided by Vapor Filled Capillary or Capillary with Bulb Sensing Element