Selectable DHWP
Selectable/adjustable DHWP protection
Selectable/adjustable boost feature
Simple adjustment of reset curve
High Limit Set point-The High Limit becomes the upper limit for the operating set point
The operating set point can not be set higher than this value
The High Limit is set to protect the boiler and hydronic system from excessive temperature
DHW Set point-The Operating Set point is set to the DHW Set point when the Control or Outdoor Reset Option Card DHW input is energized
This set point is set equal to the Indirect Water Heater manufacturer's recommended water temperature
High Boiler Water Temperature-The High Boiler Water Temperature (also known as the "Boiler Water Design Temperature") set point is set to the lowest boiler water temperature that will heat the home on the home's design day
This adjustment typically depends on the type and quantity radiation (heating element) installed in the home
Hot Water LF Module
IQ LWCO Option Cards add a low water cut-off function to boilers
LWCO Option Cards plug into the IQ Option Panel and connect to the system-mounted sensor with a single-wire connection
IQ LWCO Option Cards feature built-in diagnostics, probe signal strength display