Ignition Sequence includes timed trial for Ignition
Continuous retry trials for Ignition to Lockout
The Control Communicates Directly with the ST9160 Electronic Fan Timer in Typical Forced Warm Air Furnace Application
It Can Directly Interface with the Appropriate Power Supplies and a System Thermostat for Additional Appliance Application
When Controlled Directly by a Thermostat the Control Does Not Provide a Postpurge Function, as Power to the Control is Removed when the Thermostat Call for Heat Ends
One-Second Maximum Closing Time
Continuously Displays the Valve Position with a Red Indicator When Open and a Yellow Indicator When Closed
Mount in any Position Directly to Valve Bonnet with Three Setscrew
Provide Final Safety Shut-Off Service When Used with V5055 or V5097 Gas Valve
One-Second Maximum Closing Time
Continuously Displays the Valve Position with a Red Indicator When Open and a Yellow Indicator When Closed
Mount in any Position Directly to Valve Bonnet with Three Setscrew
Provide Final Safety Shut-Off Service When Used with V5055 or V5097 Gas Valve
One-Second Maximum Closing Time
Continuously Displays the Valve Position with a Red Indicator When Open and a Yellow Indicator When Closed
Mount in any Position Directly to Valve Bonnet with Three Setscrew
Provide Final Safety Shut-Off Service When Used with V5055 or V5097 Gas Valve
Magnetically Operated, Normally Closed
Provide Instantaneous Action When Energized
On Power Failure, Valve Closes in One Second Maximum
Use in any Position, Directly in Pipe Line or on Support Bracket
Replace the Solenoid Coil without Removing the Valve Body from the Piping Connections
Provide On-Off Control of Natural, LP and Manufactured Gases to Pilot Burners in Industrial and Commercial Applications
Provide Instantaneous Action When Energized
On Power Failure, Valve Closes in One Second Maximum
Use in any Position, Directly in Pipe Line or on Support Bracket
Replace the Solenoid Coil without Removing the Valve Body from the Piping Connections
Straight-Through Valve Pattern
WT8840 Water Heater Control is Designed for Use in Standing Pilot Applications Using an Immersion Well for Water Temperature Sensing
The WT8840 is Powered from a Thermopile Heated by the Standing Pilot Flame
Temperature Control as Well as Water Temperature Limit Function
Compact Size
Solenoid-Operated First Automatic Valve Opens on Thermostat Call for Heat, Closes When Call for Heat Ends
Diaphragm Operated Second Automatic Valve Opens Under Control of Regulator, Closes If Gas or Power Supply is Interrupted
All Adjustments, Wiring Connections and Pilot Outlet are Accessible from Top of Control
Adjustable Servo Regulator Effectively Maintains Almost Constant Gas Output Pressure Under Wide Fluctuations in Gas Supply Pressure
On-Off Lighting Sequence
Easy to install, adjust and service
All adjustments and connections are accessible from top of control
Add separate energy cutoff (ECO) where codes call for dual safety shutoff
Complete safety shutoff on pilot flame failure
LITE-RITE (OFF-PILOT-ON) lighting sequence