Magnetically Operated, Normally Closed
Provide Instantaneous Action When Energized
On Power Failure, Valve Closes in One Second Maximum
Use in any Position, Directly in Pipe Line or on Support Bracket
Replace the Solenoid Coil without Removing the Valve Body from the Piping Connections
Provide On-Off Control of Natural, LP and Manufactured Gases to Pilot Burners in Industrial and Commercial Applications
Provide Instantaneous Action When Energized
On Power Failure, Valve Closes in One Second Maximum
Use in any Position, Directly in Pipe Line or on Support Bracket
Replace the Solenoid Coil without Removing the Valve Body from the Piping Connections
Straight-Through Valve Pattern
Transformer powers low voltage control systems and provides overload protection
Low voltage terminal board provides convenient connections for thermostat and heating and cooling equipment wiring
Relay is easily replaced without disturbing wiring
Spring Returns Motor to Start Position on Power Failure
Drive Shafts Located on Both Sides of Motor
Adjustable Auxiliary Switch for Cascading Motors or Operating Auxiliary Equipment
Thermal Breaker for Overload Protection During Lifting Stroke or If Motor Stalls
Spring Return Motors for 2-Position Back Draft, Outdoor Air Changeover, Zone or Minimum Position Damper Control
Operate Outdoor Air Dampers for Combustion or Makeup Air in Residential and Light Commercial Applications
Operate Changeover Dampers for Heating and Cooling Systems
Operate Minimum Position Dampers for Ventilation and Similar Applications
Include Internal Spat Switch for Controlling Auxiliary Equipment, Additional Motors or to Provide a Burner Interlock Switch
Spring Returns Motor to Start Position on Power Failure
Drive Shafts Located on Both Sides of Motor
Adjustable Auxiliary Switch for Cascading Motors or Operating Auxiliary Equipment
Thermal Breaker for Overload Protection During Lifting Stroke or if Motor Stall
WT8840 Water Heater Control is Designed for Use in Standing Pilot Applications Using an Immersion Well for Water Temperature Sensing
The WT8840 is Powered from a Thermopile Heated by the Standing Pilot Flame
Temperature Control as Well as Water Temperature Limit Function
Compact Size
Solenoid-Operated First Automatic Valve Opens on Thermostat Call for Heat, Closes When Call for Heat Ends
Diaphragm Operated Second Automatic Valve Opens Under Control of Regulator, Closes If Gas or Power Supply is Interrupted
All Adjustments, Wiring Connections and Pilot Outlet are Accessible from Top of Control
Adjustable Servo Regulator Effectively Maintains Almost Constant Gas Output Pressure Under Wide Fluctuations in Gas Supply Pressure
On-Off Lighting Sequence