 S2K Commerce - Products Dropdown
				
 				S2K Commerce - Products Dropdown
			
			
			
				
				 S2K Commerce - Order Entry
				
 				S2K Commerce - Order Entry
			
			
			
				Use with Honeywell Flame Safeguard Primary Safety Controls and Burners Requiring Ultraviolet Flame Detection
C7027 Mounts on a 1/2 Inch Sighting Pipe by Using an Integral Collar
Detectors Can be Wired in Parallel for Difficult Sighting Applications
C7027 Seals Against Pressures up to 5 PSI When Correctly Installed
Allows for Blast Tube Mounting Due to Compact Size
HotRod EX Replaces Replaces Over 200 Igniter Models
Robust Nitride Igniter Design for Longer Life and Fewer Callbacks
Nitride Igniters with 14.5 Inch and 15.5 Inch Leads-Stripped Ends
Universal and Standard Mounting Brackets and 2 Ceramic Wire Nuts
Replaces Most Silicon Carbide Igniters Including Many Carborundum Carbide Application
The Small Size of these Devices Enable their Application to Flame Detection in Installations where Space is Limited
the Holder and Flame rod Assemblies Facilitate Flame Proving on Gas Burners or Gas Ignited Oil Burners which are Controlled by Electronic Flame Safeguard Systems
Use on Industrial Flame-Retention Gas Burner Nozzles
Works with Honeywell Flame Safeguard Controls Requiring Rectification Type Flame Detector
Mounts in Areas with Limited Space Because Flame Rod Can be Cut to Desired Length
Uses Rajah Electrical Connector
Push-In Clip, Split Nut and Adapter Assembly for Easy Pilot Burner Installation
Male Nut Connector for Pilotstat Safety Control Power Units
Push-In Clip, Split Nut and Adapter Assembly for Easy Pilot Burner Installation
Male Nut Connector for Pilotstat Safety Control Power Units
Proven, Reliable Temperature Control
Many Flexible Versions to Meet Your Application Needs
Panels Can be Used with Staged Gas, Oil or Electric Heat
Modulating Gas, Hot Water or Steam Heat and Direct Expansion or Modulating Chilled Water Cooling
Control up to 3 On-Off Heat or Cool Stages or up to 10 On-Off Heat and/or Cool Stages Using W975 Satellite Sequencers
Modulating Dc Current Signal Controls Economizer Heating or Cooling Valve Motors
T7067 Dual Set Point Thermostat/Transmitter Located in Controlled Space Provides Heating and Cooling Input Signal Based on Space Demand
C7046A Sensor Located in Discharge Air Duct Provides Heating/Cooling Anticipation and Economizer Modulating Low Limit Signal
System Cycles All Stages Off on Power Interruption
When Power is Restored, System Sequences Required Stages on with Timed Inter-Stage Delay
Push-In Clip, Split Nut and Adapter Assembly for Easy Pilot Burner Installation
Male Nut Connector for Pilotstat Safety Control Power Units
Push-In Clip, Split Nut and Adapter Assembly for Easy Pilot Burner Installation
Male Nut Connector for Pilotstat Safety Control Power Units