Z6_GHK6HJC0OG6S20Q8HU3K6R0G63
Z7_GHK6HJC0OG6S20Q8HU3K6R0GM5
Z7_GHK6HJC0OG6S20Q8HU3K6R0GM7
Z7_GHK6HJC0OG6S20Q8HU3K6R0Q22
|◀ 1249 - 1260 of 1547 ▶|
View:
4-3/16" x 3-3/32" x 4-1/2",120 VAC at 60 Hz, 3/4 HP Horsepower, SPDT, AC Operated, Electrical Fan Center

Provides overload protection for transformer

Convenient connections for thermostat and heating and cooling equipment wiring

Can be mounted in any indoor location without additional enclosure

Relay is easily replaced without disturbing wiring

Includes relay enclosure

Item#:
72525
Manufacturer Item:
R8239A1052/U
Manufacturer:
RESIDEO USA LLC
You must be logged in to order this item. Log in here
120/240 VAC, 24 V AC 60 Hz Coil, SPDT, Double Quick-Connect/Lead Wire Terminal, AC Operated, Fan Relay

Molded Terminal Numbers and Circuit Diagram on Top of Relay Provide Easy Identification for Wiring and Checking System

Untapped Coil Assures Cooler Operation

Laminated Magnet Construction for Higher Efficiency

Base Designed for Easy Replacement of Competitive Relay

Item#:
72520
Manufacturer Item:
R8225A1017/U
Manufacturer:
RESIDEO USA LLC
You must be logged in to order this item. Log in here
1-13/16" x 13-1/4" x 1-13/16", 13" Insertion, 40 to 220 Deg F, Discharge Duct Mount, Averaging, Temperature Sensor

Use to Troubleshoot System Operation

Platinum Positive Temperature Coefficient Sensor

Factory Calibrated

No Settings or Field Calibration Required

Item#:
70302
Manufacturer Item:
C7100A1015/U
Manufacturer:
HONEYWELL BUILDING/INTERNATION
You must be logged in to order this item. Log in here
2.17" x 0.81" x 4.25", -40 to 150 Deg F, +/-5%, Discharge Duct Mount, Analog, Economizer Enthalpy Sensor

Solid State Elements Sense Enthalpy (Temperature and Humidity), Use Two Sensors for Differential Control, Maximizing Energy Savings

Use One Sensor in Outdoor Air for Single Sensor Control, Use Two Sensors, One in Return Air and One in Outdoor Air for Differential Control

Mount in any Position up to 200 Ft (61 M) Away from Economizer Logic Module

Item#:
70304
Manufacturer Item:
C7400A2001/U
Manufacturer:
HONEYWELL BUILDING/INTERNATION
You must be logged in to order this item. Log in here
2-1/2" x 3/4" x 2", 40 to 110 Deg F, Bracket Mount, Solid State, Mixed Air Temperature Sensor

Uses thermistor sensing element in ventilation duct systems

Negative temperature coefficient (NTC) causes resistance to decrease as sampled air temperature increases

Requires no settings or calibration

Mounts on mounting bracket with four screws (not supplied)

Item#:
70303
Manufacturer Item:
C7150B1004/U
Manufacturer:
HONEYWELL BUILDING/INTERNATION
You must be logged in to order this item. Log in here
15 A at 120 VAC/10 A at 250 VAC/5 A at 24 VDC Resistive, 333 Deg F, Type A Style, Thermal Cut Out for Air Conditioner

Provides reliable back-up protection for temperature controlling thermostats

Item#:
75617
Manufacturer Item:
STC4333
Manufacturer:
SEALED UNIT PARTS CO INC
You must be logged in to order this item. Log in here
15 A at 120 VAC/10 A at 250 VAC/5 A at 24 VDC Resistive, 300 Deg F, Type A Style, Thermal Cut Out for Air Conditioner

Provides reliable back-up protection for temperature controlling thermostats

Item#:
75616
Manufacturer Item:
STC4300
Manufacturer:
SEALED UNIT PARTS CO INC
You must be logged in to order this item. Log in here
13.8 A at 120 VAC/8 A at 240 VAC Fan, 4.4 A at 120 VAC Limit Full Load, 90 to 120 Deg F Fan, 150 to 250 Deg F Limit, SPST, Fan and Limit Control

Time Start Fan Control for Heat Assist

Time Delay Turns ON Blower as Function of Time and Temperature after Call for Heat

Turns Off Blower as a Function of Temperature at Dial Setting for Fan

Adjustable Furnace Temperature Limit to Match Existing Setting

Item#:
75614
Manufacturer Item:
FALTS57C05T120A
Manufacturer:
SEALED UNIT PARTS CO INC
You must be logged in to order this item. Log in here
This item has been discontinued
7" L, 13.8 A at 120 VAC/8 A at 240 VAC FLA, 82.8 A at 120 VAC/48 A at 240 VAC LRA, 80 to 110 Deg F, SPST, Fan Control

Time Delay Turns on Blower as Function of Time and Temperature after Call for Heat

Turns OFF Blower as a Function of Temperature at Dial Setting for Fan

Item#:
75606
Manufacturer Item:
FA47TS7110
Manufacturer:
SEALED UNIT PARTS CO INC
You must be logged in to order this item. Log in here
13.8 A at 120 VAC/8 A at 240 VAC Fan, 4.4 A at 120 VAC Limit Full Load, 90 to 120 Deg F Fan, 150 to 250 Deg F Limit, Fan and Limit Control

Adjustable Fan Off Setting

Adjustable Differential Setting

Adjustable Furnace Temperature Limit to Match Existing Setting

Item#:
75605
Manufacturer Item:
FAL7C05TD120A
Manufacturer:
SEALED UNIT PARTS CO INC
You must be logged in to order this item. Log in here
1-1/4" x 1-1/4", NPT x NPT, 1/2 PSI, Die-Cast Aluminum, Straight-Through, Diaphragm Gas Valve

Close Firmly with Diaphragm that is Both Weight and Spring Loaded

Two Second Maximum Closing Time

Valve Closes on Power Failure, Recommended for Final Shut-Off Service

Set Opening Time with Various Sized Bleed Orifices or Adjustable Bleed Valve

Item#:
73456
Manufacturer Item:
V88A1626/U
Manufacturer:
HONEYWELL BUILDING/INTERNATION
You must be logged in to order this item. Log in here
36", Intermittent Pilot, Cable Assembly with Right Angle Boot on the Igniter End and Straight Boot on the Module End for S86/S87 Gas Ignition Module
Item#:
74788
Manufacturer Item:
392125-2/U
Manufacturer:
RESIDEO USA LLC
You must be logged in to order this item. Log in here
|◀ 1249 - 1260 of 1547 ▶|
View: