S2K Commerce - Products Dropdown
S2K Commerce - Order Entry
Use in Intermittent Ignition Applications
Capable of Zone Control with Zone Valves
Circulator Zone Control with Zach and or Terminals on R8182D,E,H,J 8 Flame Failure During the Running Cycle Results in a 45 Second Attempt to Restart
If Unsuccessful, Safety Shut-Off Occurs, Requiring Manual Reset before Burner Can be Restarted
R8182D,E,F Mount Directly on Burner
R8182H,J Mount on 4 x 4 in Junction Box and Include 5 Foot (1.5 Meter) Armored Capillary with Remote Sensor
C554A Cadmium Sulfide Flame Detector and a 24 Volt AC Thermostat Required
Controls oil burner, oil valve and the ignition transformer in response to a call for heat
Solid state flame sensing circuit
LED on terminal strip indicates system lockout
Enclosed safety switch with external reset button
Manual trip lever opens safety switch for system maintenance
For mounting on a standard 4 in. x 4 in. junction box or direct mounting on burner housing
Provides overload protection for transformer
Convenient connections for thermostat and heating and cooling equipment wiring
Can be mounted in any indoor location without additional enclosure
Relay is easily replaced without disturbing wiring
Includes relay enclosure
Molded Terminal Numbers and Circuit Diagram on Top of Relay Provide Easy Identification for Wiring and Checking System
Untapped Coil Assures Cooler Operation
Laminated Magnet Construction for Higher Efficiency
Base Designed for Easy Replacement of Competitive Relay
Use to Troubleshoot System Operation
Platinum Positive Temperature Coefficient Sensor
Factory Calibrated
No Settings or Field Calibration Required