S2K Commerce - Products Dropdown
S2K Commerce - Order Entry
Spring Return Motors for 2-Position Back Draft, Outdoor Air Changeover, Zone or Minimum Position Damper Control
Operate Outdoor Air Dampers for Combustion or Makeup Air in Residential and Light Commercial Applications
Operate Changeover Dampers for Heating and Cooling Systems
Operate Minimum Position Dampers for Ventilation and Similar Applications
Include Internal Spat Switch for Controlling Auxiliary Equipment, Additional Motors or to Provide a Burner Interlock Switch
Spring Returns Motor to Start Position on Power Failure
Drive Shafts Located on Both Sides of Motor
Adjustable Auxiliary Switch for Cascading Motors or Operating Auxiliary Equipment
Thermal Breaker for Overload Protection During Lifting Stroke or if Motor Stall
WT8840 Water Heater Control is Designed for Use in Standing Pilot Applications Using an Immersion Well for Water Temperature Sensing
The WT8840 is Powered from a Thermopile Heated by the Standing Pilot Flame
Temperature Control as Well as Water Temperature Limit Function
Compact Size
Solenoid-Operated First Automatic Valve Opens on Thermostat Call for Heat, Closes When Call for Heat Ends
Diaphragm Operated Second Automatic Valve Opens Under Control of Regulator, Closes If Gas or Power Supply is Interrupted
All Adjustments, Wiring Connections and Pilot Outlet are Accessible from Top of Control
Adjustable Servo Regulator Effectively Maintains Almost Constant Gas Output Pressure Under Wide Fluctuations in Gas Supply Pressure
On-Off Lighting Sequence
Design for Interrupted Ignition with Intermittent Pilot on Gas Burners and Interrupted or Intermittent Ignition on Oil Burners
Recycles If Flame Signal Lost while in Run Failure to Establish Pilot Results in a Lockout
Safe-Start Check Prevents Start-Up If Flame-Simulating Failure Occurs in Flame Detector Circuit
Includes SPDT Alarm Contacts
Solid State Circuitry, Eliminates Warm-Up and Increases Resistance to vibration
Mounts and Removes Easily through Use of Captive Mounting Screws
Mounting Base is Made of Strong Thermoplastic
Easy to install, adjust and service
All adjustments and connections are accessible from top of control
Add separate energy cutoff (ECO) where codes call for dual safety shutoff
Complete safety shutoff on pilot flame failure
LITE-RITE (OFF-PILOT-ON) lighting sequence
Solenoid operated first automatic valve opens on thermostat call for heat
Closes when call for heat ends
Diaphragm operated second automatic valve opens under control of the regulator
Closes if gas or power supply is interrupted
Meet codes requiring dual safety shutoff
All adjustments, wiring connections and pilot outlet are accessible from top of control
ON-OFF lighting sequence