5-1/4" x 3-7/16" x 7-1/8", 120 VAC 60 Hz, 200 PSI Immersion Well, Gas Media, SPST, Multi-Function, Combination Protectorelay and Hydronic Heating Controller

Use in Intermittent Ignition Applications

Capable of Zone Control with Zone Valves

Circulator Zone Control with Zach and or Terminals on R8182D,E,H,J 8 Flame Failure During the Running Cycle Results in a 45 Second Attempt to Restart

If Unsuccessful, Safety Shut-Off Occurs, Requiring Manual Reset before Burner Can be Restarted

R8182D,E,F Mount Directly on Burner

R8182H,J Mount on 4 x 4 in Junction Box and Include 5 Foot (1.5 Meter) Armored Capillary with Remote Sensor

C554A Cadmium Sulfide Flame Detector and a 24 Volt AC Thermostat Required

Item#:
72503
Manufacturer Item:
R8182D1079/U
Manufacturer:
RESIDEO-ADEMCO
You must be logged in to order this item. Log in here
120/240 VAC 50/60 Hz, 45 Sec, Intermittent Pilot, Automatic, Remote Lockout, Oil Burner Control

Controls oil burner, oil valve and the ignition transformer in response to a call for heat

Solid state flame sensing circuit

LED on terminal strip indicates system lockout

Enclosed safety switch with external reset button

Manual trip lever opens safety switch for system maintenance

For mounting on a standard 4 in. x 4 in. junction box or direct mounting on burner housing

Item#:
72506
Manufacturer Item:
R8184G4009/U
Manufacturer:
RESIDEO-ADEMCO
You must be logged in to order this item. Log in here
4-3/16" x 3-3/32" x 4-1/2",120 VAC at 60 Hz, 3/4 HP Horsepower, SPDT, AC Operated, Electrical Fan Center

Provides overload protection for transformer

Convenient connections for thermostat and heating and cooling equipment wiring

Can be mounted in any indoor location without additional enclosure

Relay is easily replaced without disturbing wiring

Includes relay enclosure

Item#:
72525
Manufacturer Item:
R8239A1052/U
Manufacturer:
RESIDEO-ADEMCO
You must be logged in to order this item. Log in here
120/240 VAC, 24 V AC 60 Hz Coil, SPDT, Double Quick-Connect/Lead Wire Terminal, AC Operated, Fan Relay

Molded Terminal Numbers and Circuit Diagram on Top of Relay Provide Easy Identification for Wiring and Checking System

Untapped Coil Assures Cooler Operation

Laminated Magnet Construction for Higher Efficiency

Base Designed for Easy Replacement of Competitive Relay

Item#:
72520
Manufacturer Item:
R8225A1017/U
Manufacturer:
RESIDEO-ADEMCO
You must be logged in to order this item. Log in here
Item#:
7013059
Manufacturer Item:
27J32
You must be logged in to order this item. Log in here
1-13/16" x 13-1/4" x 1-13/16", 13" Insertion, 40 to 220 Deg F, Discharge Duct Mount, Averaging, Temperature Sensor

Use to Troubleshoot System Operation

Platinum Positive Temperature Coefficient Sensor

Factory Calibrated

No Settings or Field Calibration Required

Item#:
70302
Manufacturer Item:
C7100A1015/U
Manufacturer:
HONEYWELL BUILDING/INTERNATION
You must be logged in to order this item. Log in here
2.17" x 0.81" x 4.25", -40 to 150 Deg F, +/-5%, Discharge Duct Mount, Analog, Economizer Enthalpy Sensor

Solid State Elements Sense Enthalpy (Temperature and Humidity), Use Two Sensors for Differential Control, Maximizing Energy Savings

Use One Sensor in Outdoor Air for Single Sensor Control, Use Two Sensors, One in Return Air and One in Outdoor Air for Differential Control

Mount in any Position up to 200 Ft (61 M) Away from Economizer Logic Module

Item#:
70304
Manufacturer Item:
C7400A2001/U
Manufacturer:
HONEYWELL BUILDING/INTERNATION
You must be logged in to order this item. Log in here
2-1/2" x 3/4" x 2", 40 to 110 Deg F, Bracket Mount, Solid State, Mixed Air Temperature Sensor

Uses thermistor sensing element in ventilation duct systems

Negative temperature coefficient (NTC) causes resistance to decrease as sampled air temperature increases

Requires no settings or calibration

Mounts on mounting bracket with four screws (not supplied)

Item#:
70303
Manufacturer Item:
C7150B1004/U
Manufacturer:
HONEYWELL BUILDING/INTERNATION
You must be logged in to order this item. Log in here
15 A at 120 VAC/10 A at 250 VAC/5 A at 24 VDC Resistive, 333 Deg F, Type A Style, Thermal Cut Out for Air Conditioner

Provides reliable back-up protection for temperature controlling thermostats

Item#:
75617
Manufacturer Item:
STC4333
Manufacturer:
SEALED UNIT PARTS CO INC
You must be logged in to order this item. Log in here
15 A at 120 VAC/10 A at 250 VAC/5 A at 24 VDC Resistive, 300 Deg F, Type A Style, Thermal Cut Out for Air Conditioner

Provides reliable back-up protection for temperature controlling thermostats

Item#:
75616
Manufacturer Item:
STC4300
Manufacturer:
SEALED UNIT PARTS CO INC
You must be logged in to order this item. Log in here
7", 90 to 120 Deg F (Fan Off), 150 to 250 Deg F (Limit), SPST, Adjustable, Furnace Fan/Limit Control

Short Cycle and Brown Out Protection for Compressors

Adjustable Limit Temperature

Time delay turns on blower as function of time and/or temperature after Call for Heat

Time start fan control for heat assist

Turns OFF blower as a function of temperature at dial setting for fan

Adjustable furnace temperature limit to match existing setting

Item#:
75619
Manufacturer Item:
FALTS57C65T120A
Manufacturer:
SEALED UNIT PARTS CO INC
You must be logged in to order this item. Log in here
13.8 A at 120 VAC/8 A at 240 VAC Full Load, 60 to 140 Deg F, SPST, Fan Control

Incorporates Temperature Adjustment to Match Existing Setting

Item#:
75613
Manufacturer Item:
F21413A14025C
Manufacturer:
SEALED UNIT PARTS CO INC
You must be logged in to order this item. Log in here