Refrigeration System - Multi-Circuit, Copper Tube Coil Extra large surface provides maximum cooling efficiency, excellent heat transfer and low air resistance
Precise circuiting gives uniform refrigerant distribution
Refrigeration System - Coil is constructed of precisely spaced ripple edged aluminum fins fitted to durable seamless, rifled copper tubes
Rifled tubing provides enhanced heat transfer which results in maximum coil performance when combined with fin design
Fins are strengthened to resist bending and are equipped with collars that grip tubing for maximum contact area
Flared tubing connections and silver soldering provide tight, leak-Proof joints
Long life copper tubing is corrosion-resistant and easy to field service
Coil is thoroughly factory tested under high pressure to ensure leak-Proof construction
Expansion Valve
Refrigerant Piping and Drain Connections - Refrigerant line inlets (knockouts) are provided on both sides of the cabinet
Refrigerant lines require sweat connections and are made internal to the cabinet
Condensate drain outlet extends outside the cabinet for ease of connection. Condensate drain can be relocated to other side of cabinet and can be repositioned for horizontal air flow applications
Control Box - Control box located in separate compartment in unit cabinet
Low voltage terminal strip factory installed
Blower contactor furnished and factory installed in control box
Cabinet - Cabinet is constructed of Heavy Gauge, pre-painted steel for superior rust and corrosion protection
Cabinet is completely lined with thick fiberglass insulation resulting in quiet and efficient operation
Closed-cell foam on top mullion between the blower and coil section reduces heat transfer through cabinet and prevents moisture build-up on outside of cabinet
Supply and return air duct flanges are furnished for field installation. See dimension drawings
Service access is provided on three sides of unit
Large removable panels provide complete service access on one side of unit
Electrical inlets are conveniently located in the cabinet
Drain Pan - Deep, corrosion resistant plastic drain pan
Reversible drain pan allows for drain outlets on either end of cabinet and can be repositioned for horizontal air flow applications
Drain pan is removable from either side in both horizontal and vertical applications
Blow-off baffle and extended drip shield collects condensate from the coil and directs it to the drain pan
Refrigerant - Units operate with chlorine-free, ozone friendly, R-410A
Outdoor Coil Fan - Direct drive fan(s) moves large volumes of air uniformly through entire condenser coil(s) for high refrigerant cooling capacity
Upward discharge of air reduces operating sound levels and prevents damage to lawns, shrubs and walkways
Fan motors are totally enclosed, overload protected and equipped with a rain shield
Fan service access is accomplished by removal of fan guard(s) or removal of access panel
Copper Tube/Enhanced Fin Coil - Units are equipped with a wrap-around "U" shaped coil (072-090-120 models) or two "L" shaped coils
Coils are constructed of precisely spaced ripple-edge aluminum fins machine fitted to seamless copper tubes
Lanced fins provide maximum exposure of fin surface to air stream resulting in excellent heat transfer
Fins equipped with collars that grip tubing for maximum contact area
Flared shoulder tubing connections and machine brazed silver soldering provide tight, leak-Proof joints
Long life copper tubing is corrosion-resistant and easy to field service
Thoroughly factory tested under high pressure to ensure leak-Proof construction
Completely accessible for cleaning
High Pressure Switch - Shuts off unit if abnormal operating conditions cause discharge pressure to rise above setting
Protects the compressor from excessive condensing pressure
Manual reset
Loss of Charge Switch - Shuts off unit if liquid line pressure falls below setting
Provides loss of charge and freeze-up protection
Automatic reset
Hi-Capacity Drier - Drier traps moisture or dirt that could contaminate the refrigerant system
Refrigerant Lines and Service Valves - Suction and liquid lines are located on corner of unit cabinet and are made with sweat connections
Fully serviceable suction and liquid line service valves provide complete service access to refrigerant system
Suction valve can be fully shut off, while liquid valve can be front seated to manage refrigerant charge while servicing system Accessible outside of unit cabinet
Compressor - Compressor features high efficiency with uniform suction flow, constant discharge flow and high volumetric efficiency and quiet operation
Compressor consists of two involute spiral scrolls matched together to generate a series of crescent shaped gas pockets between them
During compression, one scroll remains stationary while the other scroll orbits around it
Gas is drawn into the outer pocket the pocket is sealed as the scroll rotates
Crankcase Heater - Crankcase heater(s) prevents migration of liquid refrigerant into compressor(s) and ensures proper compressor lubrication
Cabinet - Heavy gauge, pre-painted steel cabinet provides superior rust and corrosion protection
Removable panels allow access for unit servicing
Heavy Duty steel base channels raise the unit off of mounting surface away from damaging moisture Unit lifting holes and forklift slots furnished in base rails
Outdoor Coil Fans-One Outdoor Fan-ELS072 and ELS090, Two Outdoor Fans-ELS120 and ELS150, Four Outdoor Fans-ELS180 and ELS240, Direct drive fans moves large volumes of air uniformly through entire condenser coil for high refrigerant cooling capacity, Totally enclosed fan motors, Overload protected, Rain shield furnished
Copper Tube/Enhanced Fin Coils, Wrap-around U Shaped Coil-ELS072-090-120 models, Two L Shaped Coils-ELS150-180-240 models, Ripple-edge aluminum fins, Seamless copper tube construction, Lanced fins for maximum fin surface exposure, Fin collars grip tubing for maximum contact area, Flared shoulder tubing connections, Machine brazed silver soldering, Factory tested under high pressure, Completely accessible for cleaning
CC High Pressure Switch-Protects the system from high pressure conditions, Manual reset
Loss of Charge Switch-Shuts off unit if liquid line pressure falls below setting, Provides loss of charge and freeze-up protection
Automatic reset Hi-Capacity Driers-Traps moisture or dirt
Refrigerant Lines and Service Valves-Suction and liquid lines located on corner of unit, Sweat connections, See dimension drawings, Fully serviceable suction and liquid line service valves provide complete service access to refrigerant system, Suction valve can be fully Shut-Off, while liquid valve can be front seated to manage refrigerant charge while servicing system, Accessible outside of unit cabinet
SCROLL COMPRESSORS-One Two-Stage Compressor-ELS072S4S, ELS090S4S and ELS120S4S models, Two-Single-Stage Compressors-ELS120S4D, ELS150S4D, ELS180S4D and ELS240S4D, High efficiency with uniform suction flow, Constant discharge flow, high volumetric efficiency and quiet operation, Low gas pulses during compression reduces operational sound levels, Compressor motor is internally protected from excessive current and temperature, Muffler in discharge line reduces operating sound levels, Compressor is installed in the unit on resilient rubber mounts for vibration free operation
CABINET-Heavy-gauge, pre-painted steel cabinet, Removable panels for unit servicing, Heavy duty steel base rails raise the unit off of mounting surface, Unit lifting holes and forklift slots furnished in base rails, See dimension drawings
Control Box-Control box located in separate compartment in unit cabinet, All controls are pre-wired at the factory, Control box is large enough for field installed DDC or other field supplied control modules