Z6_GHK6HJC0OG6S20Q8HU3K6R0G63
Z7_GHK6HJC0OG6S20Q8HU3K6R0GM5
Z7_GHK6HJC0OG6S20Q8HU3K6R0GM7
Z7_GHK6HJC0OG6S20Q8HU3K6R0Q22
|◀ 85 - 96 of 420 ▶|
View:
Item#:
85564
Manufacturer Item:
ML14XP1-060-233
Manufacturer:
ARMSTRONG AIR COOLING
You must be logged in to order this item. Log in here
Item#:
85563
Manufacturer Item:
ML14XP1-048-233
Manufacturer:
ARMSTRONG AIR COOLING
You must be logged in to order this item. Log in here
115000 BTU/Hr Cooling, 208/230 VAC, 11.2 EER/12.9 IEER, R410A, Upflow/Horizontal, Split Air Handler Indoor Unit

Refrigeration System - Multi-Circuit, Copper Tube Coil Extra large surface provides maximum cooling efficiency, excellent heat transfer and low air resistance

Precise circuiting gives uniform refrigerant distribution

Refrigeration System - Coil is constructed of precisely spaced ripple edged aluminum fins fitted to durable seamless, rifled copper tubes

Rifled tubing provides enhanced heat transfer which results in maximum coil performance when combined with fin design

Fins are strengthened to resist bending and are equipped with collars that grip tubing for maximum contact area

Flared tubing connections and silver soldering provide tight, leak-Proof joints

Long life copper tubing is corrosion-resistant and easy to field service

Coil is thoroughly factory tested under high pressure to ensure leak-Proof construction

Expansion Valve

Refrigerant Piping and Drain Connections - Refrigerant line inlets (knockouts) are provided on both sides of the cabinet

Refrigerant lines require sweat connections and are made internal to the cabinet

Condensate drain outlet extends outside the cabinet for ease of connection. Condensate drain can be relocated to other side of cabinet and can be repositioned for horizontal air flow applications

Control Box - Control box located in separate compartment in unit cabinet

Low voltage terminal strip factory installed

Blower contactor furnished and factory installed in control box

Cabinet - Cabinet is constructed of Heavy Gauge, pre-painted steel for superior rust and corrosion protection

Cabinet is completely lined with thick fiberglass insulation resulting in quiet and efficient operation

Closed-cell foam on top mullion between the blower and coil section reduces heat transfer through cabinet and prevents moisture build-up on outside of cabinet

Supply and return air duct flanges are furnished for field installation. See dimension drawings

Service access is provided on three sides of unit

Large removable panels provide complete service access on one side of unit

Electrical inlets are conveniently located in the cabinet

Drain Pan - Deep, corrosion resistant plastic drain pan

Reversible drain pan allows for drain outlets on either end of cabinet and can be repositioned for horizontal air flow applications

Drain pan is removable from either side in both horizontal and vertical applications

Blow-off baffle and extended drip shield collects condensate from the coil and directs it to the drain pan

Item#:
85361
Manufacturer Item:
ELA120S4D-1Y
Manufacturer:
ARMSTRONG AIR COMMERCIAL
You must be logged in to order this item. Log in here
15 Ton, 208/230 VAC 60 Hz 3-Phase, 12 EER, R-410A, Standard Efficiency, Dual Circuit, Split System Air Handler

Multi-Circuit, Copper Tube Coil-Extra large surface provides maximum cooling efficiency, excellent heat transfer and low air resistance, Coils on 090-240 models are face split with separate circuits, each circuit has its own expansion valve, Precise circuiting gives uniform refrigerant distribution, Coil is constructed of precisely spaced ripple edged aluminum fins fitted to durable seamless, rifled copper tubes

Rifled tubing provides enhanced heat transfer which results in maximum coil performance when combined with fin design, Fins are strengthened to resist bending and are equipped with collars that grip tubing for maximum contact area, Flared tubing connections and silver soldering provide tight, leak proof joints, Long life copper tubing is corrosion-resistant and easy to field service, Coil is thoroughly factory tested under high pressure to ensure leak proof construction

Expansion Valve-For use with R-410A systems, Factory installed and piped, Multi-circuit coils are equipped with one thermal expansion valve per circuit, Valves are sized for best performance, 090 and 120 models have internal check valves for use with heat pump systems

Refrigerant Piping and Drain Connections-Refrigerant line inlets (knockouts) are provided on both sides of the cabinet, Refrigerant lines require sweat connections and are made internal to the cabinet, Condensate drain outlet extends outside the cabinet for ease of connection, Condensate drain can be relocated to other side of cabinet and can be repositioned for horizontal air flow applications

External Filter Rack-Filter rack design permits quick and easy removal of filters for servicing, Heavy-gauge galvanized steel cabinet is completely insulated with thick, foil-faced fiberglass insulation and painted to match the unit, Furnished and shipped inside the unit for field installation, Must be field assembled, 2Inch thick, MERV 8 pleated media filters are furnished as standard

Belt Drive Blower-072-090-120-150 models are equipped with a single blower wheel, 180 and 240 models have dual blower wheels, Centrifugal belt driven blowers deliver large air volumes quietly and with low power consumption, Blower wheels are Heavy Duty, with forward curved blades and double inlet, Wheels are statically and dynamically balanced to eliminate vibration and designed to give maximum air delivery, Bearings are Heavy Duty, permanently sealed and lubricated, Belt tension is automatically controlled by auto tensioning device

Single Zone VAV Supply Fan VFD Kit-Variable frequency drive (VFD) and control stages the supply air blower airflow, Designed for use on dual-stage split systems the VFD alters the frequency and voltage of the power supply to control blower motor speed and airflow Supply air blower has two speeds

Control Box-Located in separate compartment in unit cabinet, Low voltage terminal strip factory installed, Blower contactor furnished and factory installed in control box, All controls are pre-wired at the factory

Cabinet -Heavy-gauge, pre-painted steel for superior rust and corrosion protection, Completely lined with thick fiberglass insulation resulting in quiet and efficient operation, Closed-cell foam on top mullion between the blower and coil section reduces heat transfer through cabinet and prevents moisture build-up on outside of cabinet, Supply and return air duct flanges are furnished for field installation, Service access provided on three sides of unit, Large removable panels provide complete service access on one side of unit, Electrical inlets are conveniently located in the cabinet

Drain Pan-Deep, corrosion resistant plastic drain pan, Reversible drain pan allows for drain outlets on either

Item#:
85365
Manufacturer Item:
ELA180S4D-1Y
Manufacturer:
ARMSTRONG AIR COMMERCIAL
You must be logged in to order this item. Log in here
86000 BTU/Hr Cooling, 208/230 VAC, 11.2 EER/14.4 IEER, R410A, Upflow/Horizontal, Split Air Handler Indoor Unit

Refrigeration System - Multi-Circuit, Copper Tube Coil Extra large surface provides maximum cooling efficiency, excellent heat transfer and low air resistance

Precise circuiting gives uniform refrigerant distribution

Refrigeration System - Coil is constructed of precisely spaced ripple edged aluminum fins fitted to durable seamless, rifled copper tubes

Rifled tubing provides enhanced heat transfer which results in maximum coil performance when combined with fin design

Fins are strengthened to resist bending and are equipped with collars that grip tubing for maximum contact area

Flared tubing connections and silver soldering provide tight, leak-Proof joints

Long life copper tubing is corrosion-resistant and easy to field service

Coil is thoroughly factory tested under high pressure to ensure leak-Proof construction

Expansion Valve

Refrigerant Piping and Drain Connections - Refrigerant line inlets (knockouts) are provided on both sides of the cabinet

Refrigerant lines require sweat connections and are made internal to the cabinet

Condensate drain outlet extends outside the cabinet for ease of connection. Condensate drain can be relocated to other side of cabinet and can be repositioned for horizontal air flow applications

Control Box - Control box located in separate compartment in unit cabinet

Low voltage terminal strip factory installed

Blower contactor furnished and factory installed in control box

Cabinet - Cabinet is constructed of Heavy Gauge, pre-painted steel for superior rust and corrosion protection

Cabinet is completely lined with thick fiberglass insulation resulting in quiet and efficient operation

Closed-cell foam on top mullion between the blower and coil section reduces heat transfer through cabinet and prevents moisture build-up on outside of cabinet

Supply and return air duct flanges are furnished for field installation. See dimension drawings

Service access is provided on three sides of unit

Large removable panels provide complete service access on one side of unit

Electrical inlets are conveniently located in the cabinet

Drain Pan - Deep, corrosion resistant plastic drain pan

Reversible drain pan allows for drain outlets on either end of cabinet and can be repositioned for horizontal air flow applications

Drain pan is removable from either side in both horizontal and vertical applications

Blow-off baffle and extended drip shield collects condensate from the coil and directs it to the drain pan

Item#:
85359
Manufacturer Item:
ELA090S4D-1Y
Manufacturer:
ARMSTRONG AIR COMMERCIAL
You must be logged in to order this item. Log in here
Manual, Air Damper for KCA-036/KCA-048/KCA-060/KCA-072/KCA-090 Packaged Electric Rooftop Unit
Item#:
61677
Manufacturer Item:
15D18
Manufacturer:
ARMSTRONG COMMERCIAL ACCE
You must be logged in to order this item. Log in here
Supply and Return, Ceiling Diffuser Transition for TG150 Packaged Gas/Electric Rooftop Unit
Item#:
65969
Manufacturer Item:
49K56
Manufacturer:
ARMSTRONG COMMERCIAL ACCE
You must be logged in to order this item. Log in here
Horizontal Low Profile, Barometric Relief Damper with Exhaust Hood for ZGA092 Packaged Gas/Electric Rooftop Unit
Item#:
65967
Manufacturer Item:
53K04
Manufacturer:
ARMSTRONG COMMERCIAL ACCE
You must be logged in to order this item. Log in here
Step-Down, Ceiling Diffuser for ZGA150/ZGB150 Packaged Gas/Electric Rooftop Unit
Item#:
63138
Manufacturer Item:
13K63
Manufacturer:
ARMSTRONG COMMERCIAL ACCE
You must be logged in to order this item. Log in here
Relief Damper, Barometric, Horizontal, Rooftop Unit Relief Damper for KCA-156/KCA-180/KCB-180 Packaged Electric Rooftop Unit
Item#:
63131
Manufacturer Item:
16K99
Manufacturer:
ARMSTRONG COMMERCIAL ACCE
You must be logged in to order this item. Log in here
26", Standard, Horizontal, Roof Curb for KHA-180/KHA-240 Packaged Heat Pump Rooftop Unit
Item#:
63122
Manufacturer Item:
11T89
Manufacturer:
ARMSTRONG COMMERCIAL ACCE
You must be logged in to order this item. Log in here
Single/Differential Temperature Control for TH024/TH030/TH036/TH048/TH060B/TH060S/TH072 Packaged Heat Pump Rooftop Unit
Item#:
63066
Manufacturer Item:
76M37
Manufacturer:
ARMSTRONG COMMERCIAL ACCE
You must be logged in to order this item. Log in here
|◀ 85 - 96 of 420 ▶|
View: