58500 BTU/Hr Cooling, 460 VAC, 11 EER/14 SEER, R410A, 2-Stage, Direct Drive, Packaged Gas/Electric Rooftop Unit

Heating System - Aluminized steel inshot burners, direct spark ignition, electronic flame sensor, combustion air inducer, redundant automatic single or dual stage gas valve with manual shut-off

Heat Exchanger - Tubular construction, aluminized steel, life cycle tested

Stainless Steel Heat Exchanger is required if mixed air temperature is below 45 Deg F

Electronic Pilot Ignition - Electronic spark igniter provides positive direct ignition of burners on each operating cycle

The system permits main gas valve to stay open only when the burners are proven to be lit

Should a loss of flame occur the gas valve closes, shutting off the gas to the burners Ignition module has LED to indicate status and aid in troubleshooting

Watchguard circuit on module automatically resets ignition controls after one hour of continuous thermostat demand after unit lockout, eliminating nuisance service calls

Ignition control is factory installed in the controls section

Limit Controls - Heat limit controls protect heat exchanger and other components from overheating

Safety Switches - Flame roll-out switch, flame sensor and combustion air inducer proving switch protect system operation

Single Speed Scroll Compressor - Scroll compressors for high performance, reliability and quiet operation

Resiliently mounted on rubber grommets for quiet operation

Compressor Crankcase Heater - Protects against refrigerant migration that can occur during low ambient operation

Thermal Expansion Valve - Assures optimal performance throughout the application range

Removable element head

Filter/Drier - High capacity filter/drier protects the system from dirt and moisture

High Pressure Switch - Protects the compressor from overload conditions such as dirty condenser coils, blocked refrigerant flow or loss of outdoor fan operation

Freezestat - Protects the evaporator coil from damaging ice build-up due to conditions such as low/no air flow or low refrigerant charge

Eco-Last Coil System - Condenser coil features lightweight, all aluminum brazed fin construction

Outdoor Coil Fan Motor - Thermal overload protected, totally enclosed, permanently lubricated sleeve (024, 030, 036 and 048 models) or ball bearings (060, 072, 074 and 090 models), shaft up, wire basket mount

Outdoor Coil Fan - PVC coated fan guard furnished

Construction - Heavy Gauge steel panels and full perimeter heavy gauge galvanized steel base rail provides structural integrity for transportation, handling and installation

Base rails have rigging holes Three sides of the base rail have fork slots

Raised edges around duct and power entry openings in the bottom of the unit provide additional protection against water entering the building

Power/Gas Entry - Electrical and gas lines can be brought through the unit base or through horizontal access knock- outs

Exterior Panels - Constructed of heavy gauge, galvanized steel with a two-layer enamel Painted finish

Insulation

Access Panels

Hinged Access Panels

Item#:
83915
Manufacturer Item:
KGB060S4DH-G
Manufacturer:
ARMSTRONG AIR COMMERCIAL
You must be logged in to order this item. Log in here
This item has been discontinued and replaced by item 
6 Ton, 460 VAC 60 Hz 3-Phase, 11.2 EER, 15 IEER, R-410A, 2nd Generation, Packaged Gas/Electric Rooftop Unit

Heating System-Aluminized steel inshot burners, direct spark ignition, electronic flame sensor, combustion air inducer, redundant automatic single or dual stage gas valve with manual shut-off

Heat Exchanger-Tubular construction, aluminized steel, life cycle tested

Stainless Steel Heat Exchanger is required if mixed air temperature is below 45 Deg F

Electronic Pilot Ignition-Electronic spark igniter provides positive direct ignition of burners on each operating cycle

The system permits main gas valve to stay open only when the burners are proven to be lit

Should a loss of flame occur the gas valve closes, shutting off the gas to the burners Ignition module has LED to indicate status and aid in troubleshooting

Watchguard circuit on module automatically resets ignition controls after one hour of continuous thermostat demand after unit lockout, eliminating nuisance service calls

Ignition control is factory installed in the controls section

Limit Controls-Heat limit controls protect heat exchanger and other components from overheating

Safety Switches-Flame roll-out switch, flame sensor and combustion air inducer proving switch protect system operation

Single Speed Scroll Compressor-Scroll compressors for high performance, reliability and quiet operation

Resiliently mounted on rubber grommets for quiet operation

Compressor Crankcase Heater-Protects against refrigerant migration that can occur during low ambient operation

Thermal Expansion Valve-Assures optimal performance throughout the application range

Removable element head

Filter/Drier-High capacity filter/drier protects the system from dirt and moisture

High Pressure Switch-Protects the compressor from overload conditions such as dirty condenser coils, blocked refrigerant flow or loss of outdoor fan operation

Freezestat-Protects the evaporator coil from damaging ice build-up due to conditions such as low/no air flow or low refrigerant charge

Eco-Last Coil System-Condenser coil features lightweight, all aluminum brazed fin construction

Outdoor Coil Fan Motor-Thermal overload protected, totally enclosed, permanently lubricated sleeve (024, 030, 036 and 048 models) or ball bearings (060, 072, 074 and 090 models), shaft up, wire basket mount

Outdoor Coil Fan-PVC coated fan guard furnished

Construction-Heavy Gauge steel panels and full perimeter heavy gauge galvanized steel base rail provides structural integrity for transportation, handling and installation

Base rails have rigging holes Three sides of the base rail have fork slots

Raised edges around duct and power entry openings in the bottom of the unit provide additional protection against water entering the building

Power/Gas Entry-Electrical and gas lines can be brought through the unit base or through horizontal access knock- outs

Exterior Panels-Constructed of heavy gauge, galvanized steel with a two-layer enamel Painted finish

Insulation

Access Panels

Hinged Access Panels

Item#:
84740
Manufacturer Item:
KGB074S4TH-G_ECONOMI
Manufacturer:
ARMSTRONG AIR COMMERCIAL
You must be logged in to order this item. Log in here
This item has been discontinued and replaced by item 
Item#:
7000345
Manufacturer Item:
KGC092S4MM-G FA893
You must be logged in to order this item. Log in here
This item has been discontinued and replaced by item 
Item#:
7000346
Manufacturer Item:
KGC120S4MH-Y FA945
You must be logged in to order this item. Log in here
This item has been discontinued and replaced by item 
Item#:
7000347
Manufacturer Item:
KGC120S4MH-Y FA947
You must be logged in to order this item. Log in here
This item has been discontinued and replaced by item 
208/230 VAC 60 Hz 3-Phase, 15 kW, Electric Heat Kit for ZCB036/ZCB048/ZCB060/ZCB074 Packaged Rooftop Unit
Item#:
86465
Manufacturer Item:
99W04
Manufacturer:
ARMSTRONG COMMERCIAL ACCE
You must be logged in to order this item. Log in here
This item has been discontinued and replaced by item 
Item#:
81753
Manufacturer Item:
EWC1512P30
Manufacturer:
ARMSTRONG AIR MAGIC-PAKS
You must be logged in to order this item. Log in here
This item has been discontinued and replaced by item 
Item#:
81720
Manufacturer Item:
4HP18V36
Manufacturer:
DUCANE COOLING
You must be logged in to order this item. Log in here
This item has been discontinued and replaced by item 
35000 BTU/Hr Cooling, 208/230 VAC 1-Phase, 14 SEER/11.7 EER, R-410A, Packaged Gas/Electric Rooftop Unit

Quick and Easy Retrofit - Fast installation for replacement of many existing rooftop units - fits high volume competitor's roof curbs

R-410A Refrigerant - Environmentally friendly

Single Speed Scroll Compressor - Furnished on 036 through 060 models

Allows rooftop units to deliver just the necessary amount of cooling needed to meet the space's demand

Eco-Last Coil System - Smaller, lighter condenser coil

High Pressure Switch - Protects compressor

Direct Drive (ECM) or Belt Drive Blower Motors - Multi-tap ECM direct drive motors (all 036 thru 060 models)

Belt drive motors (036 thru 074 3-Phase models) Two-speed belt drive motor (low static/high static) 074 models maximizes air performance

Downflow or Horizontal Airflow - Easy field conversion

Two Fork Lift Slots on Three Sides - Easy to pick up and transport units from almost any angle

Corrosion Resistant Drain Pan - Provides application flexibility, durability and improved serviceability

Common Components - Many maintenance items are standard throughout the entire product line, reducing the need to carry different parts to the job or maintain in inventory

Cooling System Cooling Capacity Specify nominal cooling capacity of the unit

All control voltage is provided via a 24V (secondary) transformer with inline fuse protection

Heat/Cool Staging

Capable of up to 2-heat/2-cool staging with a thermostat

Night Setback Mode Saves energy by closing outdoor air dampers and operating supply fan on thermostat demand only

Cabinet - Heavy Gauge steel panels and full perimeter heavy gauge galvanized steel base rail provides structural integrity for transportation, handling and installation

Base rails have rigging holes Three sides of the base rail have fork slots

Raised edges around duct and power entry openings in the bottom of the unit provide additional protection against water entering the building

Airflow Choice Units are shipped in downflow (vertical) configuration, can be field converted to horizontal airflow configuration without the need of a kit

Power Entry Electrical lines can be brought through the unit base or through horizontal access knock-outs

Exterior Panels - Constructed of heavy gauge, galvanized steel with a two-layer enamel Painted finish

Insulation All panels adjacent to conditioned air are fully insulated with non- hygroscopic fiberglass insulation

Access Panels Access panels are provided for the compressor, heating, controls, blower and air filter/economizer section

Item#:
83962
Manufacturer Item:
ZGB036S4EY-P
Manufacturer:
ARMSTRONG AIR COMMERCIAL
You must be logged in to order this item. Log in here
This item has been discontinued and replaced by item 
45500 BTU/Hr Cooling, 208/230 VAC 1-Phase, 14 SEER/11 EER, R-410A, Packaged Gas/Electric Rooftop Unit

Quick and Easy Retrofit - Fast installation for replacement of many existing rooftop units - fits high volume competitor's roof curbs

R-410A Refrigerant - Environmentally friendly

Single Speed Scroll Compressor - Furnished on 036 through 060 models

Allows rooftop units to deliver just the necessary amount of cooling needed to meet the space's demand

Eco-Last Coil System - Smaller, lighter condenser coil

High Pressure Switch - Protects compressor

Direct Drive (ECM) or Belt Drive Blower Motors - Multi-tap ECM direct drive motors (all 036 thru 060 models)

Belt drive motors (036 thru 074 3-Phase models) Two-speed belt drive motor (low static/high static) 074 models maximizes air performance

Downflow or Horizontal Airflow - Easy field conversion

Two Fork Lift Slots on Three Sides - Easy to pick up and transport units from almost any angle

Corrosion Resistant Drain Pan - Provides application flexibility, durability and improved serviceability

Common Components - Many maintenance items are standard throughout the entire product line, reducing the need to carry different parts to the job or maintain in inventory

Cooling System Cooling Capacity Specify nominal cooling capacity of the unit

All control voltage is provided via a 24V (secondary) transformer with inline fuse protection

Heat/Cool Staging

Capable of up to 2-heat/2-cool staging with a thermostat

Night Setback Mode Saves energy by closing outdoor air dampers and operating supply fan on thermostat demand only

Cabinet - Heavy Gauge steel panels and full perimeter heavy gauge galvanized steel base rail provides structural integrity for transportation, handling and installation

Base rails have rigging holes Three sides of the base rail have fork slots

Raised edges around duct and power entry openings in the bottom of the unit provide additional protection against water entering the building

Airflow Choice Units are shipped in downflow (vertical) configuration, can be field converted to horizontal airflow configuration without the need of a kit

Power Entry Electrical lines can be brought through the unit base or through horizontal access knock-outs

Exterior Panels - Constructed of heavy gauge, galvanized steel with a two-layer enamel Painted finish

Insulation All panels adjacent to conditioned air are fully insulated with non- hygroscopic fiberglass insulation

Access Panels Access panels are provided for the compressor, heating, controls, blower and air filter/economizer section

Item#:
83963
Manufacturer Item:
ZGB048S4EY-P
Manufacturer:
ARMSTRONG AIR COMMERCIAL
You must be logged in to order this item. Log in here
This item has been discontinued and replaced by item 
35000 BTU/Hr Cooling, 208/230 VAC, 14 SEER/11.7 EER, R410A, 1-Stage, 1-Speed Belt Drive, Packaged Gas/Electric Rooftop Unit

Quick and Easy Retrofit - Fast installation for replacement of many existing rooftop units - fits high volume competitor's roof curbs

R-410A Refrigerant - Environmentally friendly

Single Speed Scroll Compressor - Furnished on 036 through 060 models

Two-Stage Scroll Compressor - Furnished on 074 models. Allows rooftop units to deliver just the necessary amount of cooling needed to meet the space's demand

Eco-Last Coil System - Smaller, lighter condenser coil

High Pressure Switch - Protects compressor

Direct Drive (ECM) or Belt Drive Blower Motors - Multi-tap ECM direct drive motors (all 036 thru 060 models). Belt drive motors (036 thru 074 3-Phase models) Two-speed belt drive motor (low static/high static) 074 models maximizes air performance

Downflow or Horizontal Airflow - Easy field conversion

Two Fork Lift Slots on Three Sides - Easy to pick up and transport units from almost any angle

Corrosion Resistant Drain Pan - Provides application flexibility, durability and improved serviceability

Common Components - Many maintenance items are standard throughout the entire product line, reducing the need to carry different parts to the job or maintain in inventory

Cooling System Cooling Capacity Specify nominal cooling capacity of the unit

All control voltage is provided via a 24V (secondary) transformer with inline fuse protection

Heat/Cool Staging

Capable of up to 2-heat/2-cool staging with a thermostat

Night Setback Mode Saves energy by closing outdoor air dampers and operating supply fan on thermostat demand only

Cabinet - Heavy Gauge steel panels and full perimeter heavy gauge galvanized steel base rail provides structural integrity for transportation, handling and installation

Base rails have rigging holes Three sides of the base rail have fork slots

Raised edges around duct and power entry openings in the bottom of the unit provide additional protection against water entering the building

Airflow Choice Units are shipped in downflow (vertical) configuration, can be field converted to horizontal airflow configuration without the need of a kit

Power Entry Electrical lines can be brought through the unit base or through horizontal access knock-outs

Exterior Panels - Constructed of heavy gauge, galvanized steel with a two-layer enamel Painted finish

Insulation All panels adjacent to conditioned air are fully insulated with non- hygroscopic fiberglass insulation

Access Panels Access panels are provided for the compressor, heating, controls, blower and air filter/economizer section

Item#:
85960
Manufacturer Item:
ZGB036S4BM-Y
Manufacturer:
ARMSTRONG AIR COMMERCIAL
You must be logged in to order this item. Log in here
This item has been discontinued and replaced by item 
Item#:
7000457
Manufacturer Item:
ZGB060S4BH-G CC636
You must be logged in to order this item. Log in here