S2K Commerce - Products Dropdown
S2K Commerce - Order Entry
Prevents ice from building up on the outdoor unit base when operating in heating mode for an extended period of time in a very low temperature, high humidity condition
Controlled by outdoor unit
Works during defrost operation and energizes when outdoor temperature drops below 36 Deg F
PAC-646BH-E connect to CN714 on MXZ-2C20NA2
Allows for a third party building management system to control a Mitsubishi Electric Cooling and Heating CITY MULTIĀ®, M-Series or P-Series indoor unit
One MelcoBEMS MINI (A1M) per indoor unit
Indoor Unit Connection: CN105 - IT Terminal
12 Volt DC power from indoor unit CN105 Connector
Compatible with MAC-333IF connector CN505 IT
requires additional 12VDC power supply
Prevents ice from building up on the outdoor unit base when operating in heating mode for an extended period of time in a very low temperature, high humidity condition
Controlled by outdoor unit
Works during defrost operation and energizes when outdoor temperature drops below 36 Deg F
Prevents ice from building up on the outdoor unit base when operating in heating mode for an extended period of time in a very low temperature, high humidity condition
Controlled by outdoor unit
Works during defrost operation and energizes when outdoor temperature drops below 36 Deg F
PAC-SJ20BH-E connects SS on Control board of MXZ-8C48NA, 8C60NA, PUZ-A36,42NKA7, PUZ-HA42NKA, PUMY-P36,48,60NKMU2
Allows for a separate power supply to MVZ and PVA indoor units when connected with select outdoor units
Allows for additional indoor unit configurations when installed on units connected with select outdoor units
Allows for electric heat operation when power to outdoor unit is interrupted or in Error
Fits between 16 Inch joists
Stylish, square design panel
Built in condensate lift mechanism (19.6 Inch)
Serviceable from the bottom (electrical and flare connection)
Adjustable fan speeds and vane directions
Industry leading slim body realized a simple design with linear beauty
AHRI Certified
Energy StarĀ® Rated
Patented a single burner combustion system including a one-piece burner assembly
115 Volt Open Fan Motor with Internal Overload Protection
Integrated circuit board with diagnostic indicator lights
Multi-try direct ignition with timed lockout
Fan relay (included on the circuit board)
Single-stage natural gas valve
Vibration/noise isolated fan motor
Sealed control compartment houses all electrical components
48 frame, ball bearing, PSC venter motor
4-point Suspension
External terminal strip for 24 volt wiring
Sealed junction box for supply wiring
External Gas Connection
Fully gasketed door panel with safety door switch
Full Fan Guard Engineered for Safety
Improved Cabinet Design with Less Visible Hardware